SysTec IT3000Ex, W&M Approved Industrial Weighing Terminal for use in Ex Zones 1, 2, 21 and 22
- Stainless steel housing with mounting brackets for desk-top, wall-mount or panel-mount installation
- ATEX approval:
- II 2(2)G Ex e ib mb [ib] IIC T4 Gb (gas)
- II 2(2)D Ex ib tb [ib] IIIC T125°C Db (dust)
- 2 intrinsically safe digital inputs (5 V) and 2 intrinsically safe digital outputs to connect piezo electric valves (5 V). Option for 1 plug-on intrinsically safe serial interface, SIM10mA Exi, to connect printer, PC or remote display via the SysTec interface module. Alternative option for an intrinsically safe optical interface SIMLWL-Ex to connect to several IT3000Ex units to a fiber-optic system located in the hazardous area. Connection to PC in safe area via SysTec separation module.
- Separation Module for installation in Safe Area:
- TS3000 with RS232, 20mA, or RS485 interface
- Fieldbus-separation module with Profibus-DP or Profinet or Ethernet/IP or Modbus® TCP
- Analog output, configurable for current output 0/4–20 mA or voltage output 0/2–10 V DC
- 8 I/O relay module TS-REL485 with 8 opto-isolated inputs and 8 relay outputs.
- Separation Module for installation in Ex Area:
- TS-RDIT1-Ex: Ex-i separation module with IT1 remote display
- TS-WLAN-Ex: WLAN separation module to connect to a local network and optional voltage supply for indicator
- TS-Scanner-Ex: Ex-i separation module with battery guard to connect a handheld scanner BCS 3608Ex-IS and optional voltage supply for an IT3000Ex
Other Weighing Indicator ATEX Version:
Weighing Application: Panatronik